The automatic release of novec 1230 fluid is controlled by a. Kidde fire suppression system engineered for use with 3m. Trim components are required to operate the clean agent cylinders. Double action manual releasing stations shall be provided at each exit of the protected area and shall, when activated, immediately release the inergen agent and cause all audiblevisual alarms to activate. This manual, pn 45n1230m001, is to be used by qualified and factorytrained personnel, knowledgeable of nfpa standards and any other applicable standards in effect. It is a liquid at room temperature, with a low vapor pressure, which allows for ease in handling, storage, and shipping. It is one of the newest clean agents in halon alternatives. Warning test cylinder, shut valve, and quick connect must have a pressure rating equal to or higher than the system cylinder the sample is being obtained from. The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve.
It is essen tial for the safe operation of the system that all safety information and operating instructions provided in this manual be observed. Systems using novec 1230 fluid are designed to flood a space with the gas to a design. Novec 1230 fluid leaves no residue and is safe for use in occupied spaces. Operate the lever, following the instructions on the lever or. Please download the installation manual appropriate for your chosen firetrace fire suppression system or application. Three valve sizes sv, mv, and lv series each with multiple cylinder size options allow individual cylinder fills ranging. Empty the extinguisher of all pressure and 3m novec using a listed. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems for mining, marine, industrial, commercial and retail use. An operating manual can be ordered from the manufacturer page 2 with the part number 932161. A master cylinder slave is the left one b cylinder valve.
Shutdown all forced ventilation devices, engines, generators and electrical systems. Novec 1230 fluid 0 fire detection 0 10 20 30 40 50 60 70 80 90 100 110 120 140 150 agent flow time fire extinguished time seconds engineered for fast extinguishment novec 1230 fluid knocks down fires in less than half the time of co 2 agents. Engineered hydraulic flow program used to predict the two phase flow of novec 1230 through a pipe network. Novec 1230 fire suppression system for fire protection. Manufactured by 3m, it is electrically nonconductive and environmentally sustainable. Ds1080 lv series using novec 1230 fluid janus fire systems. In janus fire systems clean agent fire extinguishing systems, the novec 1230 fluid is stored as a liquid in specially designed steel cylinder assemblies fitted with forged brass, differential pressureoperated valves. It shall not be used as a substitute in determining material and quantity requirements as defined in kidde fire systems design manuals and applicable nfpa standards. The cylinder location should ideally be in a clean area away from direct heat.
Test cylinder and tee assembly must be clean and a vacuum pulled on both components prior to obtaining a sample. When it comes to service, remember that your toyota dealer knows your vehicle very. Kidde engineered fire suppression system designed for use with 3m novec 1230 fire protection fluid 900 lb. Novec 1230 fluid is low in toxicity and environment impact. If outages do occur, our crews are ready to respond.
With 50 years of experience, gielle is the specialist in fire safety. Operation of fireboy fire extinguisher manual operation of ga1xxxxnvcb systems 1. The design, installation, testing and maintenance of the clean agent fire. Clean agent suppression systems using novec 1230 fluid. Novec 1230 fluid has been sold into clean agent fire suppression for 15 years and into more than a 100 countries. Over a wide range of temperatures, a high boiling material like novec 1230 fluid, when superpressurized with nitrogen. Ads fire suppression system using 3m novec 1230 agent. Where you are designing a novec 1230 from scratch then it wont make any difference unless you are comparing them. Learn more about our margin of safety compared to other clean agents in the novec 1230 fluid brochure pdf, 1. An optional cylinder supervisory pressure switch pn 06. A cylinder containing novec 1230 fluid should be handled carefully.
Empty the extinguisher of all pressure and 3mnovecusing a listed recharge recovery system and a bulk supply cylinder with sufficient empty capacity to accept the contents of the extinguisher. Fire suppression systems utilizing novec 1230 fluid are designed to be. Renowned for his competence reliability efficiency all over the world. Follow all of the safety procedures included on the cylinder nameplate and in this manual.
The manual valve actuator consists of a brass body, stainless steel actuation pin, and steel safety ring pin. Of course, you are always welcome to contact novec if you have questions. In addition, activation of the manual releasing stations shall cause immediate shutdown of interconnected electrical circuits. Test cylinder with shutoff valve and quick connect. The primary extinguishing mechanism of novec 1230 fluid is heat absorption, with a secondary chemical contribution from the thermal decomposition of novec 1230 fluid in the flame. Refer to design, installation, and operations manual for design concentration guidance of class b fuels or contact kidde fire systems.
This technical manual provides the necessary information for the design, installation, operation and maintenance of a chemetron fm200 sigma series engineered system. Double novec 1230 cylinder with master slave operation. Novec 1230 fire protection fluid fire protection technologies. Cylinders are finished in gloss enamel red and are available in various sizes. High performance 42 bar system kd1230 is a high performance 42 bar systemthat offers major technical and economic advantages over 25 bar systems. Having fewer cylinders also results in a system that is less complex, and typically less costly to install and maintain. Novec tm 1230 removes heat energy from the fire to the extent that the combustion reaction cannot sustain itself. The cylinder is filled with the extinguishing agent and then pressurized. The cylinder should not be placed in a location where the ambient temperature is above 80 degrees centigrade. This is a single volume technical manual arra nged in 6 sections, followed by an appendix.
Illusfrations are provided throughout this manual to provide the user with both a graphic and narrative description of the ventilators operating features. Read entire instruction manual and cylinder nameplate prior to installation. Novec 1230 fire protection fluid, is a second generation clean agent fire extinguishing agent. Fm200, novec 1230 and inergen clean agent systems are covered by these. Identification of the material and supplier product name novec 1230 other names none recommended use fire protection agent for total flooding of rooms containing electrical equipment such as computer rooms as well as flammable. Remove the safety pull pin from the cylinder control head. This manual is intended to clearly and accurately reflect the kidde engineered fire suppression system designed for use with 3m novec 1230 fire protection fluid. At novec, we understand the hardships the covid19 emergency imposes on our customers we are temporarily suspending service disconnections for nonpayment and penalty fees.
Equally important, novec 1230 fluid offers zero ozone depletion potential, a 5. Where multiple cylinders are required they can be manifold together or kept separate and distributed throughout the room, this is known as a distributed cylinder system. Cylinder valve with burst disc, pressure gauge, protective neck ring, protective cylinder cap and valve cap. Customer service excellence is a corporate priority. Every effort should be made to halt unnecessary escape of 3mnovec to the atmosphere. In addition an installation and maintenance manual can be ordered from the manufacturer under part number 932159. Novec 1230 cylinder the agent storage vessel consist of a cylinder fitted with a valve and internal siphon tube, factory filled with novec 1230 and super pressurized with nitrogen to 25 bar. Novec 1230 fluid is applied as a gas, but is liquid at room temperature. Fast extinguishment helps keep fires small, giving them less chance to spread. Design, installation, operation and maintenance manual pn 45n1230m001. It has distinct environmental benefits over any other active halon alternative. If the novec 1230 fluid is discharged in 10 seconds or less, flames will be extinguished rapidly and the amount of byproducts produced will be minimal. Proceed to appropriate kidde engineered system cylinder for the hazard.
Toyota land cruiser prado owners manual pdf download. Kidde fenwal novec 1230 engineered fire suppression system, is designed to use 3m novec 1230 fire protection fluid. Novec 1230 is a chemical fire suppressant which is stored as a fire. This operaung manual for the life support products autovent 20003000 automatic ventilators has been designed for ease of use in the paramedical and field transport setting.
Novec 1230 clean agent fire suppression system is used extinguished any fire hazard. For confined spaces, the cylinders can be installed within the protected area, removing the need for a separate storage room. All electric or electronic devices must connect to the control panel in order to. Novec 1230 fluid is clean and leaves no residue, thereby eliminating costly afterfire cleanup and keeping expensive downtime to a minimum. Upon activation of the cylinder valve, the operation pressure switches contacts transfer to indicate discharge or to perform disconnectactivation required during system operation. Novec 1230 fluid is available in two sizes of containers. Nominal volume fill weight kg outlet size mm dimension a mm diameter. Its 500 psi operating pressure provides ultimate design flexibility and ensures that the necessary amount of agent reaches every corner of the protected space in under ten seconds, extinguishing a. Manual for the using kidde ads system using novec 1230 to the enduser owner. Therefore you must be very careful especially when upgrading systems from fm200 to novec 1230 to ensure the cylinder quantities, cylinder sizes and pipework size will work for novec 1230. System in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release.
In the long run novec 1230 fluid can help save space and associated cost. This means you need significantly less cylinders to store novec 1230 fluid, enabling more flexible site selection. This provides nondamaging threedimensional fire suppressing capability, making it the ideal agent for extinguishing even concealed fires in spaces where electronics or irreplaceable, missioncritical assets are stored, or where continuity of operations is crucial. Definitions novec 1230 novec 1230 is a registered trade mark of the 3m. In case of fire, do not wait for automatic actuation. Sinorix compact c an be directly installed in the enclosure to be protected. Novec 1230 is a chemical agent used primarily in total flooding systems and is the most environmentally benign of all the chemical agents. This calculation tool is intended for use in developing approximate estimates of the material and equipment budgeting purposes. Close all hatches leading to the protected compartment. These engineered systems that are employing novec 1230 fluid are typically installed in.
In addition to the information pro vided in this manual, all local accident prevention and general safety regulations applicable at the systems. Its proven quality and reliability have provided specifiers and endusers with a smart solution for their clean agent needs. Novec 1230 is low in acute toxicity, and evaporates 50 times faster than water, making it ideal for protection of sensitive assets. Attach the appropriate recharge adapter to the extinguisher operating valve on the extinguisher cylinder.
Novec 1230 fluid is a clean agent included in the nfpa 2001 standard. This cylinde r supervisory pressure switch has a 18inch npt connection, which is used on the 3inch valve only. Vsh1230 clean agent fire suppression system novec 1230. Cylinder when installing the firetrace system it is important that a suitable cylinder location is selected and that the cylinder is orientated correctly. Each suppression unit shall be equipped with its own automatic nonelectric detection system, which when actuated, automatically releases the novec 1230 agent into the hazard area. An optional cylinder supervisory pressure switch pn 06118262001 can be installed on the cylinder valve in the field if required. Environmentally friendly 3m novec 1230 clean agent 0 odp 1 gwp brass, chrome plated operating valve 125 psi operating pressure heavy duty steel cylinder, carriage and hose hanger assembly lunette coupler for towing quick release 40 ft. User manuals, perkins engine operating guides and service manuals. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems for mining, marine, industrial, commercial and retail use, gielle has got you covered. Ecsfire suppression system with novec1230 fire protection fluid august 2014 page 4 of 7 2.
The operation pressure switch is used to provide a means of detecting system activation. Kidde fire suppression system engineered for use with 3m novec 1230 fire protection fluid. Kidde fenwal novec 1230 fire suppression system fire. This also goes for the other manuals and instructions delivered together with the loader, especially the safety manual, the instruction manual rcl safety system, as well as the service booklet. Visual check of pipe network and distribution nozzles per the operation and maintenance manual. The term novec 1230 employed throughout this manual refers to the extinguishing agent dodecafluoro. At a minimum the routine maintenance will include the following. The automatic release of novec 1230 fluid is controlled by a forged brass, differential pressure operated cylinder valve connected to the neck of the cylinder.
When designing a fire suppression system using 3m novec 1230 fluid, how are agent concentrations maintained after discharge. Page 1 for your safety and comfort, read carefully and keep in the vehicle page 2 for important information about this manual and your toyota, read the follow ing pages carefully. Upon completion of installation and commissioning acceptance, the suppression system contractor shall provide two 2 copies of the design, installation, operation and maintenance manual for the using kidde ads system using novec 1230 to the enduserowner. An additional nozzle can be easily connected to pro tect an underfloor area.
Some installations use, or are in the process of converting to. Concept fire suppression ltd use hygood sapphire hardware and cylinders which are available in several different sizes from as small as 8l through to 180l. For the safety of all customers and employees, we ask that you please do not approach novec employees in the field. Continuity of operation is paramount, and those types of. Weight and pressure of the novec 1230 fluid cylinder per the operation and maintenance manual. The system shall be a kidde ecs fire suppression system with novec 1230 fire protection fluid and shall consist of novec 1230, agent cylinder s superpressurized to 360. The fireflex 1230 system uses 3m novec 1230 fire protection fluid. Novec 1230 clean agent suppression systems fire safety. Upon discharge of the preengineered novec tm 1230 fire suppression system, the extinguishing agent floods the compartment with an electrically nonconductive, noncorrosive vapor that stops the combustion process by physical means. Fm200 fire suppression system design, installation, operation and. Sapphire fire suppression systems sapphire cleanagent. Integrated fire protection systems fireflex systems. Installation and service manual that is an integral part of the uscg type.
The antirecoil safety device must be in place at all times when the cylinder is not connected to the discharge. Firetrace direct novec 1230 automatic suppression systems. The minimax mx 1230 fire extinguishing system with 3m novec 1230 fire protection fluid detects fire in its initial stage and extinguishes exceptionally fast, flooding the room in less than 10 seconds. Protect valuable equipment, people and assets with a clean agent fire suppression system using 3m novec 1230 fire protection fluid. The kd1230 system consists of 3mtm novectm 1230 fire protection fluid stored in cylinders connected to distribution pipe work and nozzles. Novec 1230 clean agent suppression systems combines outstanding extinguishing performance with an excellent environmental profile. It is nonconductive and leaves no residue, putting out fires while preserving both assets and operations. Novec 1230 is not considered to be a rcra hazardous waste. The cylinder is filled with the extinguishing agent and. Design, installation and maintenance manual part number 027650010.
1316 1463 57 1413 976 526 1021 37 467 1466 692 469 673 397 990 756 1049 936 243 1468 1015 89 1339 1440 114 800 639 399 1362 1415 1023 369